How do I find Miele dishwasher error codes? To identify a Miele dishwasher fault, look at the digital display or the flashing sequence of the “Intake/Drain” LED. Common codes include F11 (Drainage), F12/F13 (Water Intake), and F70 (Waterproof System). To access deeper diagnostics, you can enter Service Mode by holding the “Program” button while powering on the unit and pressing the button in a specific sequence.
How to Activate Miele Dishwasher Service Mode
To enter Service Mode on a Miele dishwasher, the specific sequence of button presses depends on the series and control panel layout. While the general logic is similar, the number of presses and the specific indicator lights vary.
Initial State: Ensure the dishwasher door is closed (or open depending on model’s panel access) and the unit is switched OFF.
Below is a breakdown of the entry procedures for the various models typically covered in Miele diagnostic guides:
Step-by-Step Diagnostic Access for each Miele Dishwasher Model
| Model Series / Name | Button Sequence | Acknowledgment Signal |
| Inspira & Advanta (G 118x, G 2170, G 218x) | Hold Program, turn On. Release, then press 3 times (hold 3rd press). | “Rinse & Hold” LED flashes. |
| Optima (G 1202) | Hold Start/Stop, turn On. Release, then press 3 times (hold 3rd press). | “Start/Stop” LED flashes slowly. |
| Optima, Advanta & Diamante (G 1262, G 1470, G 2020, G 2120, G 2470) | Hold Program, turn On. Release, then press 4 times. | “Intake/Drain” LED flashes. |
| LaPerla (G 283x, G 2872) | Hold Program, turn On. Release, then press 6 times. | “Intake/Drain” LED flashes rapidly. |
| Modern G-Series (Digital Display / Touch Controls) | Hold Start/Stop (or Program), turn On. Release, then press 3 times (hold 3rd press). | Display shows “Technical Service” or Software Version. |
- The Sequence: As soon as the display lights up or the machine responds, release the Program button and immediately press it 3 times in quick succession.
- The Hold: On the third press, do not release—hold the button down until the screen displays “Technical Service” or the “Rinse” LED begins to flash rapidly.
- Navigation: Use the arrow keys or the Program button to scroll through the menu. Look for options like “Fault Memory” (to see previous error codes) or “Component Test” (to manually run the motor or heater).
- Exit: To exit service mode and return to normal operation, simply turn the dishwasher OFF.
Now that you know how to enter Service Mode on your Miele dishwasher, we will now explain what each code means and what to do about it.
Miele Dishwasher Error Codes & Meanings
| Error Code | Meaning | Likely Cause |
|---|---|---|
| F00 | No fault registered | |
| F01 / F02 | Heating fault | Defective heater, wiring issue, or control board failure (short circuits) |
| F11 | Drainage fault | Clogged drain hose, blocked filter, or faulty drain pump |
| F12 | Water intake fault at start of step | Low water pressure, closed valve, clogged inlet filter |
| F13 | Water intake fault at end of step | Low water pressure, closed valve, clogged inlet filter |
| F14 | Heater pressure switch fault | Faulty pressure switch or control issue |
| F15 | Hot water intake fault | Water temperature too high or plumbing issue |
| F18 | Flow meter stationary state monitor. Water intake problem | Restricted water flow or inlet valve issue |
| F19 | Flow meter stiff and not turning freely | Flow Meter defective |
| F24 | Heater relay fault | Relay stuck or control board problem |
| F25 | Temperature sensor fault | Failed thermistor or wiring issue |
| F26 | Heater relay welded; boiling protection | Heater stuck on; control board failure |
| F32 | Door lock fault (won’t close) | Door not locking properly or faulty latch |
| F33 | Door lock blocked (won’t open) | Mechanical obstruction in door lock |
| F36 | Door lock wiring fault | Electrical issue in door lock circuit/switch defective |
| F40 | Electronics failure | Control board malfunction |
| F42 | Line frequency fault | Power supply frequency problem |
| F47 | Interface communication fault (between BAE & SLT) | Control board communication error |
| F51 | Pressure sensor fault | Faulty pressure switch or blocked air trap |
| F52 | Heater output too low | Heating element or relay issue |
| F53 | Speed sensor fault | Circulation pump speed sensor failure |
| F63 | Water path control fault | Diverter motor or water distribution issue |
| F67 | Circulation pump fault | Pump failure or blockage |
| F68 | Circulation pump blocked | Debris in pump or impeller jam |
| F69 | Circulation pump fault | Electrical or mechanical pump failure |
| F70 | Float switch activated | Leak detected in base pan |
| F78 | Circulation pump malfunction | Pump motor or electronics issue |
| F84 / F85 | Automatic detergent dispenser fault | Dispenser motor or control failure |
| F86 | Lid contact fault | Salt |
| F87 | Sensor Softener fault | |
| F88 | Turbidity sensor fault | |
| F91 | Load size registration inactive |
Important Notes
- Error codes may differ slightly by model, series, or region.
- Resetting power can clear temporary faults, but recurring codes usually indicate a mechanical or electrical problem.
- F70 (leak detected) should always be addressed immediately to prevent water damage.
How to fix Miele Error Codes F01-F14
Error Code F01 or F02: Water/Heating NTC or Leads Short-Circuited
After this fault is registered, the heating will not be activated and rinse aid will not be dispensed. Cause: NTC temperature sensor R30 or its connection leads short-circuited or open-circuited. How to Fix It:
- Check the temperature sensor and its leads for continuity. At 68°F (20°C),
the temperature sensor resistance should be approximately 14.9k
(± 750); at 77°F (25°C), approximately 12k (± 600) (guide figures only). - Check the plug connections.
- Replace the temperature sensor, if necessary.
Miele F11 Error: Drainage Issues
Symptom: Water present in an appliance and is not being drained off.
Background information: After each drain pump step, the circulation pump operates for 2 seconds and heater pressure switch B1/13 checks the water level. If it is too high (large quantity of residual water remaining in the cabinet), the drainage time is extended. If, after a further check, the water level is still too high, then the program is interrupted, the fault code is saved and the drain pump is activated.
Fault code F11 is also registered if heater relay 1K1 is not activated after the fault code F51 register check.
- Drain hose kinked
- Drain blocked.
- Ball in non-return valve in the sump has not opened (e.g., jammed).
- Foreign objects in heater pressure switch.
- Heater relay defective.
- Heater relay (coil or contacts) becomes defective during the drainage step (after fault code F51 register check).
Error Code F12: Water Intake Fault at Start of Step
Symptom: During the first 5 seconds of any water intake step, at least 15 pulses from flow meter B3/4 should be registered. If this given number of pulses is not detected, the display reads Water inlet fault and/or the “Intake/Drain” LED flashes (depending on model). The water inlet valve will be activated at 10-second intervals for one hour. The drain pump will also be activated at intervals to prevent the possibility of the appliance overflowing. All other components remain inactive. If these attempts to achieve the minimum pulse rate fail, the buzzer is activated for 2 minutes.
- On-site shutoff valve (water supply) closed
- On-site water supply not in order (water pressure below 14.5 pounds per square inch)
- Water inlet valve defective
- Flow meter B3/4 is not providing any pulses
- Remove the left side panel.
- Check that the circuit board with reed switch on flow meter B3/4 is seated
correctly. - Check that the reed switch connection plug is seated correctly.
- Replace the reed switch, if necessary.
- Check the flow meter for pulses.
a. While the appliance is in operation and no pulses are delivered, take a
magnet and pass it over the reed switch. If a pulse is then delivered,
replace the water diverter. If no pulse, replace the reed switch.
b. While the appliance is in operation and pulses are delivered,
reconnect the electrical connector to the electronic board, clear the fault and operate the appliance. If an F12 is still displayed, replace the electronic board. - Check the control lead from the electronic to flow meter B3/4.
- Replace the water diverter, if necessary.
- Flow meter electrical connection open-circuited
- Check the wires to the flow meter reed switch for continuity.
- Check the plug connections.
Error Code F13: Water Intake Fault at End of Step
Symptom: The program is interrupted and the drain pump is operated. After approximately 2 to 4 minutes, the buzzer is activated for 2 minutes.
Background information: This fault is registered when the desired number of pulses, which varies depending on the program, has not been detected within a certain given time (maximum 4 minutes).
If the selected program starts with a water softener flushing cycle, the fault code register check is carried out earlier. In the event of a fault, the selected program is interrupted after approximately 30 seconds and the fault is indicated.
Connect with an Appliance Repair Tech
Click here to use the chatbox to speak with one of our technicians.
No in-home service calls. No appointments.
- On-site water supply not in order
- Water inlet valve defective
- Flow meter B3/4 is providing too few pulses
Error Code F14: Water Intake Fault: Heater Pressure Switch
Symptom: The program is interrupted and the drain pump is operated. See Table for model-specific fault indications.
Background information: With the circulation pump operating after a water
intake step, the heater pressure switch is checked to ensure that sufficient
water pressure exists in the wash water circuit. For this the heater relay must
have been activated.
- During a heating step the heater pressure switch may have registered no or insufficient water pressure at the circulation pump.
- Heater pressure switch B1/13 defective or blocked by foreign objects.
- Circulation pump inoperative. Circulation pressure too low (no pressure at heater pressure switch). Pump may be blocked by foreign objects.
- Flow meter B3/4 defective (incorrect water quantity registered).
- Circulation pump winding overheated; winding protection has cut out.
- After a water intake step, heater pressure switch B1/13 has not opened switching steps 11–12 and 21–22. This causes the anti-stiction routine to be started.
How to Fix Miele Dishwasher Error Codes F15-F26
Error Code F15: Water Intake Fault – Hot Water
Intake temperature of the hot-water connection is too cold (below 100°F).
Error Code F18: Flow Meter Stationary State Monitor B3/4
The water inlet valve is open when it should not be (a signal to open it has not been given by the electronic). Water then flows into the appliance and unexpected pulses from the flow meter are detected. Unexpected pulses from the flow meter are also detected when the water inlet valve is not activated.
Error Code F24: Heater Relay Contact
- Heater relay contacts have fused together
- Moisture in heater relay
- Fault in the plug on the output side of the heater relay. Contamination or corrosion on the plug of the heater wiring harness can cause a bridge between contacts, which can reduce the transfer resistance below a value of 10 megaohms
Error Code F25: Target Temperature Fault
During the heating stage, the desired temperature has not been reached within the given time (minimum 75 minutes). In subsequent wash blocks, after this fault has been registered, the heater is not activated and no rinse aid is dispensed.
- Heater defective.
- Heater relay defective.
- Excess quantity of detergent or rinse aid dispensed. Excess foam has developed. Excess foam can cause a drop in water flow pressure, directly affecting the Heater pressure switch.
Error Code F26: Boiling Protection
- Temperature at NTC temperature sensor has exceeded 194°F (90°C).
- NTC temperature sensor providing inaccurate information
- Heater relay closed
How to Fix Miele Error Codes F32-F52
Error Code F32/F33: Door Lock Does Not Close
- The given time for retraction of the adjustable door lock latch from position 3 to 2, or 2 to 1 is not sufficient.
- Given time period for new positioning exceeded
Error Code F36: Door Lock Switch Defective
- S4 and S80 closed at the same time (Replace the comfort door closing aid)
Error Code F40: Electronic Fault
The electronic has a fault that cannot be repaired by the service department
(such as a hardware fault).
Error Code F42: Line Frequency Registration Fault
Main power supply not in order. A check is carried out to ensure that the line frequency is within certain valid ranges (50 ± 5 Hz or 60 ± 5 Hz). This fault is registered when it cannot clearly be established which valid range is applicable
Error Code F47: Faulty Interface Between Selection-Display
Electronic (BAE) & Control-Power Electronic (SLT)
- Communication between BAE and SLT faulty
How to Fix Miele Dishwasher Error Codes F51-
Error Code F51: Heater Pressure Switch
One second after program start, heater relay K1/1 is activated. This enables a check as to whether the contacts on heater pressure switch B1/13 have closed on switching steps 21/22 or 11/12. If the electronic receives no power, an F51 fault is stored.
- Heater relay defective; contact open.
- Heater relay solenoid defective
- Connection from heater relay to electronic is open-circuited
- Heater pressure switch open- or short-circuited.
- Foreign objects in heater pressure switch
Error Code F52: Heater Pressure Switch Has Reset During
Heating
- Excess quantity of detergent or rinse aid dispensed. Excess foam has developed.
- Heater pressure switch defective.
- Pump pressure too low.
- An item has tipped over and a large quantity of water is retained, e.g., in a bowl, and is then not available for the wash water circuit. This reduces the pump pressure.
How to Fix Miele Error Codes F53-F79
Error Code F53: Speed Sensor Fault
With the circulation pump activated the speed sensor does not provide any signals.
- Circulation pump blocked.
- Speed sensor defective
Error Code F63: Slide Shutter Fault
Even though the slide shutter motor has been activated, there is no signal change at the position switch. The slide shutter motor will be activated again whenever repositioning is required
- Position switch defective
- Connection wires open- or short-circuited
- Drive (synchronous motor) defective
- Slide shutter gearing defective.
Error Code F67: Circulation Pump Speed Too Low
The check is carried out 10 seconds after the circulation pump has started.
- Circulation pump stiff and not turning freely
- Speed sensor defective.
- Circulation pump capacitor defective
Error Code F68: Circulation Pump Operating After Shutoff
The speed sensor registers that the circulation pump is still operating even after it has been switched off. The frequency converter of the pump registers a speed signal from the
electronic, so a target speed is set.
- Speed sensor defective
- Electronic defective.
Error Code F69: Circulation Pump Blocked
With the circulation pump operating, the heater pressure switch contacts are checked. For this, the heater relay must have been activated and both electronic’s inputs must be potential-free.
- Heater pressure switch defective
- Heater relay defective
- Circulation pressure too low because circulation pump is blocked by foreign objects.
Error Code F70: Float Switch Fault
- Water in the drip pan. Changeover contact of overflow float switch B8/3 closed from 1 to 4
- Float switch defective
- Drip pan warped after transport
Error Code F78: Circulation Pump Fault
- Interrupted connection between the electronic and the circulation pump
- Faulty circulation pump (low or excess voltage, blocked, etc.).
- Frequency converter electronic defective
Error Code F79: Circulation Pump Interaction Fault
- Faulty interaction between the frequency converter electronic of the circulation pump and the electronic (SLT).
- Frequency converter electronic defective
- Control electronic (SLT) defective
How to Fix Miele Error Codes F84-F91
Error Code F84: Slide Shutter Positioning Fault
- Position switch defective – Replace the circulation pump.
- Drive (synchronous motor) defective – Replace the circulation pump
- Slide shutter mechanism defective – Replace the circulation pump
- Turbidity sensor connection wires open-circuited
Error Code F85: Slide Shutter Signal Change Fault
Symptom: Even though the slide shutter has not been activated, a signal change has
been detected at the position switch.
If the fault is registered before the circulation pump has been activated for the first time (or before program start), the program is interrupted and the drain pump is operated.
If the fault is registered later, the fault message will be indicated in the display
at the end of the program.
- Position switch B3/12 defective; intermittent contact
- Electronic defective
Error Code F86: Salt Container Lid Contact Fault
Symptom: If the fault is detected during a program, the program will be interrupted and the drain pump will start. The display reads Close salt container lid. If the fault is detected before the start of a program, the message Close salt container lid will be displayed. Background information: This fault is detected if the reed switch is constantly open during the monitoring period
- Lid not closed.
- Magnet missing.
- Reed switch magnet defective
Error Code F87: Sensor Softener Fault
Symptom: If this fault is registered, the program is not interrupted. The fault will only be
indicated when the fault code memory is checked in the service mode.
Background information: If this fault is registered, an emergency program operates in which the reactivation start time and the switching points for the EGS (electronically controlled water softener) valve are given.
- Voltage supply (approximately 9VAC) to the sensor softener 10N1 electronic or the data connection open-circuited
- Sensor softener electronic conductivity measurement defective
Error Code F88: Turbidity Sensor Fault
- False or no values from turbidity sensor
- Foreign objects in the measurement path
- Turbidity sensor connection wires open-circuited.
Error Code F91: Load Size Registration Inactive
Symptom: If this fault is registered, the program is not interrupted. The fault will only be
indicated when the fault code memory is checked in the service mode. Background information: If this fault is registered, the water intake block will operate by taking in the default water quantity. In the subsequent additional fill, the quantity of which will normally depend on the size of the load, the water intake block is replaced by a water intake block with fixed water quantity.
- Speed sensor defective
- Water has collected in tipped-over dishes (e.g., large bowls). Subsequent water fill is not successful.
Newer Miele Dishwashers and Troubleshooting
Miele has recently expanded its lineup with the G 7000 and G 5000 series. While these models are highly rated for being whisper-quiet (as low as 38 dBA) and for innovative features like AutoDos (automatic detergent dispensing), users have reported specific technical and maintenance issues.
New Miele Model Series
The G 7000 Series is Miele’s flagship line, featuring high-end tech like the PowerDisk system and WiFi connectivity. The Miele G 7196 SCVi is a popular model in this range, known for its 3D MultiFlex Tray and QuickIntenseWash which cleans and dries in under an hour.
The G 5000 Series serves as the entry-to-mid-range tier. Models like the Miele G 5056 SCVi offer the same core Miele cleaning reliability and AutoOpen drying but often skip the automatic detergent dispensing found in the 7000 series to keep the price point more accessible.
Reported Problems & Known Issues
Despite their premium build, several common complaints have surfaced regarding these newer generations:
- Responsive Button Delay (Standby Mode): Many users report that the Power button seems unresponsive. This is often not a hardware failure but a 4-second “wake-up” delay caused by the energy management system when the machine has been idle.
- AutoDos / PowerDisk Faults (F600 series): The new automatic dispensing system can sometimes trigger F600 or F601 errors if the dispensing outlet is blocked or if the PowerDisk is not seated correctly.
- Firmware & Software Glitches: Because these are “smart” appliances, they can experience F28 errors related to drying faults that are occasionally resolved through firmware updates via the Miele@mobile app rather than physical repairs.
- Drainage Issues (F11): While not exclusive to new models, the F11 error remains common. In newer units, this is frequently caused by a misaligned drain pump cover or debris in the non-return valve.
- Rack Rusting: Some long-term users have reported bubbles in the coating or rust spots on the racks, which Miele often attributes to the use of specific harsh detergents (like plant-based powders) that may not rinse away fully in eco-modes.
Troubleshooting Guides for Other Miele Appliances:
Read: Miele Vacuum Troubleshooting Guide
Read: Miele Washers
Hi Eugene i am in the uk and have a Miele G4920 Dishwasher, it stopped a working or so week ago and came up with a F24 fault code which is a heater relay , i have changed the relay but it is still coming up with the same fault code. do i need to clear the fault code and if so how do i clear it.
Hello – we bought a Miele dishwasher floor model (G 6987 SCVi K20) from a local retailer and it’s stuck in “demo” mode. Any chance you know the button sequence for getting into service mode so we can deactivate the demo setting?
Hi Eugene, I have a G1143 (Australian model) which sometimes trips the circuit breaker (similar to misha) other times, the program stops part way with all lights flashing. Service mode gives 1 diagnostic code F14. I pulled out the circulation pump removed a small plastic debris but did not look like enough to block the flow. The heating element does not appear to have earth leakage to ground, and its 25 ohms between the contacts. I think my multi-meter measures resistance up to 20 mega ohms. I did not notice any water leaks.
I put it back together and still same symptoms. Any other ideas?
FYI: I managed to enter service mode using the instructions “For Miele Dishwasher Inspira and Diamante – G 2120/G 214x/G 2150” above. The pre-wash LED flashes to indicate that its in fault code mode and Wash/Rinse LED flashing out the fault numbers.
hi gene,I have a miele G5100 diswasher that is flashing error code F 13. Do you know how to reset error message?
I am not sure if you will be able to reset it permanently, but you can turn power OFF to the dishwasher for a couple of minutes and then turn ON.
Unfortunately, i don’t have a service manual for your model
I have a Miele G 4263 SCVi. The door on the washing liquid box has stopped opening. I’ve checked the spring and cleaned it so it’s not that. I have no error/fault code.
Any suggestions?
Cheers
You need to take the front panel off and check the resistance of the wax motor (brown color) for the dispenser box. If it shows infinite resistance, than it is faulty
thank you Eugene, sorry didnt see your response earlier. what I did was , i thought it was the drain pump ordered a new one, tested the resistance on new pump and it was same as old pump, so I put the old pump back, however i did replace the non return value while i was at and did a quick wash, the dish washer didnt trip.
as for testing the resistance heating element i will try to see where the heating element is, you wouldnt have a pic of it would you, also as for the dishwasher breaker, the dish washer is not on its own circuit, other appliances on the circuits are fine, so i am not sure if the breaker is the culprit.
thnaks
i don’t think that a non-return valve can affect somehow a dishwasher, so it is not related. Just wondering if your dishwasher plugged in the CFGI receptacle?
Hi Eugene,
have you got any information on miele G2220 model.? currently it is tripping the circuit breaker, I think it is the drain pump, but not sure how to get to it.? it starts and does the washes 30min in, then it trips. i think this is when it starts to drain and because the drain pump is faulty it is tripping no error codes or anything, do you have any infor on G2220 , how to enter error code mode etc..
many thanks in advance.
m
I can not tell you, how exactly enter a diagnostic mode for your model.
First thing, you need to check the resistance of the heating element to the ground. If the heating element is ok, replace a dishwasher breaker.
Have G2143 Miele and operates well but no display, blank and dark
indicator lights okay